Sample Analysis Requirement

  • Plant sample required 5-10g.
  • Quantitative analysis could be possible for which method is developed at CIMAP (consult before sample submission).
  • For others samples detail methodology to be provided for feasibility.
  • Marker compound 5-10mg (purity > 98%) should also be submitted along with samples (unused may be collected back).
  • Rates are for the quantification of one peak.
  • Additional charge @ Rs.1000 per maker chemical will be charged.
  • Plant sample required 5-10g.
  • Quantitative analysis could be possible for which method is developed at CIMAP (consult before sample submission).
  • For others samples detail methodology to be provided for feasibility.
  • Marker compound 5-10mg (purity > 98%) should also be submitted along with samples (unused may be collected back).
  • Rates are for the quantification of one peak.
  • Additional charge @ Rs.1000 per maker chemical will be charged.
  • Sample 500-1000g of raw material.
  • Hydro-distillation would be performed.
  • Sample 1-2ml of oil.
  • Hydro-distillate.
  • Rates are for the quantification of two major peaks.
  • Additional charge @ Rs.1000 per peak will be charged.
  • Sample 1-2ml of oil.
  • Hydro-distillate.
  • li>Rates are for the quantification of two major peaks. li>Additional charge @ Rs.1000 per peak will be charged distillate.

[300 & 500 MHz FT NMR ]

  • 5-10 mg for 1HNMR and 30- 40 mg for 13CNMR and other experiments e.g. 2D- COSY, HSQC: HMBC etc.
  • Sample must be soluble in 0.6 ml of deuterated solvent.
  • li>Solubility and nature of compound, eg. carcinogenic, toxic, explosive, hygroscopic etc. li>Structural formula (contemplated / known) to be mentioned. li>RADIOACTIVE MATERIAL should not be submitted. li>Facilities available for multinuclear and 2Dimensional homo- and hetero nuclear (inverse detection) experiments as well.
  • Sample should be ESI /APCI compatible.
  • MS/MS with APCI/ ESI (both +ve and –ve) will be provided.
  • Sample should be ESI /APCI compatible.
  • MS with APCI/ ESI (both +ve and –ve) will be provided.
  • Sample 5-10 mg KBr/Nujol/CsI/CHCl3, nature (hygroscopic,explosive,etc.)
  • Analysis of organic and Inorganic chemicals, polymers, biological samples, etc .
  • Non-invasive Analysis of organic and Inorganic chemicals, polymers, biological samples, etc.
  • Sample preparation & calibration of pH meter.
  • 20 g of sample required.
  • Sample preparation.
  • 100g of sample is required.

(Available Zn, Cu, Mg and Fe)

  • Sample preparation and calibration of ICP.
  • 10g of sample is required.

Problematic soil (Salinity stress): Na, Ca ,Mg, ESP and CEC

  • Sample preparation and calibration of Flame photometer.
  • 100g of sample is required.

ICP

(Heavy metal analysis Except Hg, As and Se )

  • Sample preparation and calibration of ICP.
  • 10g of sample is required.

Latest Updates

  • Online Registration is compulsory for using the CIMAP-CIF portal.
  • The sample analysis will be done only on the receipt of the payment.
  • Payment would be accepted by DD/NEFT only.
  • Kindly add GST 18% (w.e.f. from 1st Sep 2017) on Instrument Charges

As per new guidelines we accept the sample through on only portal analyticsir